Paper Title :
A New Fully Automated System Design For Evaluation Of Standardized And Reproducible Data In Intraoral Photography Of Gingiva

Author :Sahin Yildirim, Cem A. Gurgan, M. Yakup Sari, Emir Esim, Sertaç Savaş, Turgay Temel

Article Citation :Sahin Yildirim ,Cem A. Gurgan ,M. Yakup Sari ,Emir Esim ,Sertaç Savaş ,Turgay Temel , (2015 ) " A New Fully Automated System Design For Evaluation Of Standardized And Reproducible Data In Intraoral Photography Of Gingiva " , International Journal of Advance Computational Engineering and Networking (IJACEN) , pp. 101-105, Volume-3, Issue-10

Abstract : In spite of advanced and high technology, there is still some problems for positioning head and chin of dental patients during photographic recording. Furthermore, it is very important to get reproduciable photographic data for the evaluation of the dental treatment. In this study, a new designed system method is being introduced for the collection of standardized intraoral photographs and computer-assisted measurement of reproducible data. However, PLC based fully automated a photograpic device for fully automated intraoral photography and standart protocol for the mucogingival complex is also presented. However, the proposed fully automated system is consisted of camera equipment with two directions and head supporting linear sliding mechanism with two directions of Z axes and X axes. Keywords- PLC, gingivomorphometry, intraoral photographs,

Type : Research paper

Published : Volume-3, Issue-10


DOIONLINE NO - IJACEN-IRAJ-DOIONLINE-3104   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 88
| Published on 2015-10-13
   
   
IRAJ Other Journals
IJACEN updates
Paper Submission is open now for upcoming Issue.
The Conference World

JOURNAL SUPPORTED BY